Star out
- the modern aluminium system for designing windows and doors requiring very good thermal insulation
- thermal separator 45 mm deep, made of solid and proven materials, is an effective thermal barrier
- the same type of insulation insert in the window sash and in the window frame provides continued protection against heat losses of the whole structure
- new standard of profile and glass pane interface – increased depth improves thermal properties and structure of the system
- new type of corner section used preventing collision between the screw and the corner when screwing in surface hardware elements under the PVC groove
- possibility of adding roller hinge system hardware with very high load bearing capacity
- innovative drainage system (no visible elements stopping drainage outlets)
- the same type of corner and T connector in the external and internal cavity (reduced number of accessories, faster fabrication)
- reduced number of glazing strips and gaskets, while keeping the continuity of glazing depending on package thickness
- possibility of glazing from the inside
- option of bending profiles
- modern design
- the system is particularly recommended for low energy consumption and thermal insulation retrofitted buildings, and they also improve thermal comfort in standard object
- a wide range of colours available – RAL palette, structural colours, Wood Colour Effect, bi-colour, anodized
TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
SYSTEM | MATERIAL | DEPTH OF FRAME | DEPTH OF LEAF | GLAZING RANGE | TYPE OF WINDOWS | TYPE OF DOORS |
GT window | aluminium / thermal insulation | 90 mm |
99 mm | fix 14-72 mm / 23-81 mm | wall, fix, tilt and turn | - |
GT drzwi | aluminium / thermal insulation | 90 mm | 99 mm | 14-72 mm | - | single and double doors, outside and inside opening |
PERFORMANCE | ||||
---|---|---|---|---|
SYSTEM | THERMAL INSULATION UF* | AIR PERMEABILITY | WINDLOAD RESISTANCE | WATERTIGHTNESS |
GT window | UF od 0,73 W/m2K | Class 4; PN-EN 12207 | C4 1600Pa; EN 12210 | Class E900; EN 12208 |
GT door | Uf from 1,21 W/m2K | Class 4; EN 12207 | C4 1600Pa; EN 12210 | Class E900; EN 12208 |